3'-Dabcyl CPG Column

3'-Dabcyl CPG Column

CPG column used to 3'-label an oligonucleotide with the dabcyl quencher moiety.

Key features

Show Hide
  • Used to add a yellow-green fluorescent quencher to the 3' end of an oligonucleotide.
  • Emission range at 400-550 nm (absorption maximum, 471 nm). Alternative to BHQ-1 in certain applications.
  • 1000 Å CPG suitable for highly modified oligonucleotides (> 20mers).
Option 1: Select a Pore Size
Option 2: Select a Column Type
Option 3: Select a Scale
TBD
Add to basket to request a quote

Product information

Dabcyl is a non-fluorescent molecule, (so-called dark quencher) efficiently quenching various fluorescent dyes. It has been widely used as a quencher in diagnostic probes such as Molecular Beacons.(1) A Molecular Beacon is a hybridisation probe consisting of a fluorophore, a quencher and a defined section of the oligonucleotide sequence complementary to that of the target nucleic acid. In the inactive state, when the probe is not hybridised to its target sequence, the fluorescence energy of the fluorophore is transferred to the quencher by a process of collisional quenching. For light energy transfer to take place efficiently, both fluorophore and quencher have to be in close proximity. This requirement is accounted for in the design of Molecular Beacons in that the two parts of the stem hybridise to hold the F/Q pair in close proximity. 

Hybridisation of the Molecular Beacon probe to its target sequence results in the separation of the stem and hence the F/Q pair, resulting in fluorescence.

We offer a variety of CPG and phosphoramidite Dabcyl products for myriad applications. Since Dabcyl is stable to oligo synthesis it can be incorporated at any point in the sequence. 5’ modification is used in TwistAmp fpg probes; 3’ modification in Taqman probes, duplex Scorpions and Molecular Beacons; and internal modification has been utilised in Scorpion Primers. Deprotection of the oligo is dependent on the F/Q pair but in general is as per unmodified oligos.

Dabcyl’s absorption properties limit the range of dyes it can quench to those emitting at 400-550 nm such fluorescein and JOE (absorption maximum, 471 nm), but tends to overlap poorly with fluorophores emitting above 480 nm. However, when used in Molecular Beacons, the fluorophore and Dabcyl are brought close enough to allow a slightly broader spectrum of dyes to be quenched, thereby increasing the versatility of the Dabcyl molecule.

Although Dabcyl was originally the quencher of choice, for the most part this has been superceded by Black Hole Quenchers (BHQs) for newer applications.

Ref:

  1. Molecular beacons: probes that fluoresce upon hybridisation, S. Tyagi and F.R. Kramer, Nature Biotechnology, 14, 303-308, 1996.
Synthesizer
Column
Type/Description
Notes
MerMade 6,12
MerMade, syringe (all scales)
Pipette type column
A MerMade column is also known as a Supercolumn
MerMade 4, 48X, 96E, 192E, 192X
MerMade, Syringe (up to 1.3 mL)
Pipette type column
A MerMade column is also known as a Supercolumn
ABI 384 / 394
Luer
Barrel column with luer fitting at either end
Also known as ALL-FIT or Standard
Expedite 8909
Luer
Barrel column with luer fitting at either end
Also known as ALL-FIT or Standard
ABI3900
MerMade
Pipette type column
A MerMade column is also known as a Supercolumn
K&A H4, H8, H8SE, H2, H32, H64
Luer
Barrel column with luer fitting at either end
Also known as ALL-FIT or Standard
K&A S4CL/S8CL
Luer
  Barrel column with luer fitting at either end 
 Also known as Standard. For this instrument, we recommend the Luer (Standard) column as the ALL-FIT columns have a wider barrel.
Dr Oligo 48
MerMade
Pipette type column
A MerMade column is also known as a Supercolumn
 Dr Oligo 192XLc, 768XLc just plates 
 MerMade, Syringe (up to 1.3 mL) 
Pipette type column
A MerMade column is also known as a Supercolumn
 OligoMaker X12, 48, 192, X192, X96 
MerMade, Syringe (up to 1.3 mL)
Pipette type column
A MerMade column is also known as a Supercolumn

Applicable Products

LK2085 5'-Dabcyl-CE Phosphoramidite
LK2144 Dabcyl-dT-CE Phosphoramidite
LK2374 3'-Dabcyl CPG
LK2426 3'-Dabsyl CPG

Physical & Dilution Data

Dilution volumes (in ml) are for 0.1M solutions in 10% THF in dry acetonitrile (LK4059) for LK2144, and 0.1M solutions in dry acetonitrile (LK4050) for LK2085. Adjust accordingly for other concentrations. For µmol pack sizes, products should be diluted as 100µmol/ml to achieve 0.1M, regardless of molecular weight.

Item

Mol. Formula

Mol. Wt.

Unit Wt.

250mg

500mg

1g

LK2085 C30H45N6O3P 568.69 430.18 4.40 8.79 17.58
LK2144 C63H76N9O10P 1150.32 707.90 2.17 4.35 8.69
LK2374 - - 462.44 - - -
LK2426 - - 498.49 - - -

General

Today, the most commonly used dark quenchers are all azo based. It must be noted that as a result it is not uncommon to observe fragmentation during mass spectrometry analysis by MALDI-TOF. Dabcyl and DDQ-1 will show a fragment of M-134, BHQ™-1 shows M-298 and BHQ™-2 shows M-300.

Dissolution

Dabcyl-dT-CE Phosphoramidite (LK2144) is dissolved in 10% THF in acetonitrile, 5’-Dabcyl-CE Phosphoramidite (LK2085) in anhydrous acetonitrile.

Coupling

A 6min coupling time is recommended for the phosphoramidites. 3’-Dabcyl CPG (LK2374) and 3'-Dabsyl-CPG (LK2426) are used as per standard nucleoside supports. However, since non-nucleosidic modifications detritylate at a slower rate it is recommended to carry out an initial additional detritylation. In this case it is important not to carry out any additional capping.

Deprotection

Standard oligonucleotide deprotection conditions can be applied when deprotecting an oligo containing this modification; typically AMA, 55oC, 35min.

Storage & Stability

All compounds are stored in a freezer at -10 to -30°C. Stability of the phosphoramidites in solution is 2-3 days.

Access support

Need some support with placing an order, setting up an account, or finding the right protocol?