BHQ-3 CPG; Glycolate, Column
BHQ-3 CPG; Glycolate, Column
Key features
Show- Used to add a non-fluorescent quencher to the 3' end of an oligonucleotide.
- Maximal absorption in the 620 to 730 nm range.
- Glycolate linker for rapid cleavage of the oligonucleotide.
- 500 Å CPG suitable for high yield applications (≤ 30mers).
- 1000 Å CPG suitable for highly modified oligonucleotides (> 20mers).
Product information
Since their introduction to the DNA marketplace in 2000, the Black Hole Quenchers have become THE gold-standard quencher of choice used in qPCR probes and other FRET applications. When fluorogenic dual-labeled probes were first introduced, quenchers were often a second reporter dye, typically TAMRA. The sensitivity of these probes, such as FAM-TAMRA, is limited because the fluorescence from TAMRA can leak into the channel meant to detect FAM fluorescence. Dark quenchers, which are dyes with no native fluorescence, offer a solution to this problem. The BHQ dyes are true dark quenchers with no native emission due to their polyaromatic-azo backbone. Substituting electron-donating and withdrawing groups on the aromatic rings produces a complete series of quenchers with broad absorption curves that span the visible spectrum into the near IR region. BHQ dyes work through a combination of FRET and static quenching to enable researchers to avoid the residual background signal common to fluorescing quenchers such as TAMRA, or low signal to noise ratio. These quenchers can be paired with all common reporter dyes to construct efficiently quenched qPCR probes for multiplexing assays. In addition to quenching by FRET, BHQ dyes have also been shown to efficiently quench fluorescence through static quenching via formation of a ground state complex with the reporter dye.
BHQ quenchers have broad absorption spectra and can be paired with reporter dyes that emit in the following ranges: BHQ-0: 430-520 nm BHQ-1: 480-580 nm BHQ-2: 560-670 nm BHQ-3: 620-730 nm BHQ-10: 480-550 nm Water Soluble (WS) LGC, Biosearch Technologies offers all Black Hole Quencher products available for 3’, internal and 5’ modification of oligonucleotides with a variety of options. BHQ-1 and BHQ-2 are the more popular, either as the 5'-Phosphoramidites, the dT-Phosphoramidites or the 3'-CPGs. Only considering the excitation and emission values suggests Cy™5/Cyanine-5 and Quasar 670 require BHQ-3 for efficient quenching, however BHQ-2 is recommended because it is less susceptible to degradation. BHQ-1 is typically used to quench in the range 480 - 580 nm and can be used in conjunction with the commonly used fluorophores; e.g. FAM, TET, JOE and HEX. BHQ-2 is used to quench in the range 550 – 650 nm and is most effective in quenching fluorophores such as TAMRA, ROX, Cyanine-3, Cy3, Cy3.5™ and Red 640. We also offer Black Hole Quenchers for labelling peptides. All of our BHQ dyes are available as carboxylic acid or succinimidyl esters. Our BHQ-1 and BHQ-2 dyes are available as FMOC lysine conjugates. Our water soluble BHQ-10 is available as a carboxylic acid or succinimidyl ester.
Synthesizer
|
Column
|
Type/Description
|
Notes
|
---|---|---|---|
MerMade 6,12
|
MerMade, syringe (all scales)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
MerMade 4, 48X, 96E, 192E, 192X
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
ABI 384 / 394
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
Expedite 8909
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
ABI3900
|
MerMade
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
K&A H4, H8, H8SE, H2, H32, H64
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as ALL-FIT or Standard
|
K&A S4CL/S8CL
|
Luer
|
Barrel column with luer fitting at either end
|
Also known as Standard. For this instrument, we recommend the Luer (Standard) column as the ALL-FIT columns have a wider barrel.
|
Dr Oligo 48
|
MerMade
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
Dr Oligo 192XLc, 768XLc just plates
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
OligoMaker X12, 48, 192, X192, X96
|
MerMade, Syringe (up to 1.3 mL)
|
Pipette type column
|
A MerMade column is also known as a Supercolumn
|
Properties:
- Appearance: dark blue powder
- Absorption Maximum (Lambda Max): 672
- Extinction Coefficient at Lambda max: 42700
- Extinction Coefficient at 260 nm: 13000
Spectral properties measured in PCR buffer as 5'-labeled poly(T) oligo.
Product usage:
- Deprotection conditions: Cleave and deprotect in concentrated NH4OH for 1 hour at 60 °C (after 1 hour at 60 °C, degradation of product may occur). If product is left out in the open or exposed to heat for long periods degradation will occur.Image of cleaved and deprotected structure:
- The mass this product adds after conjugation and work-up (the additional mass seen by mass spectrometry) is: 517.66
Storage and handling:
- Shipping conditions: Ambient
- Storage conditions: -15 to -30 °C in sealed container
Access support
Need some support with placing an order, setting up an account, or finding the right protocol?
Contact us